OpenBuildings™ Designer 帮助

更改 IFC_WORKSET 的值

IFC_WORKSET 配置变量在“配置变量”对话框中处于锁定状态,在此处无法更改值。完成以下程序,更改此配置变量的值。

  1. 使用记事本等编辑器打开当前模板,例如,BuildingTemplate_US.cfg 文件。

    该文件可以在“工作集”目录中找到,如 ...\WorkSpaces\<WorkSpaceName>\Worksets

  2. 向下滚动到该文件的底部并查找 IFC 配置变量。
    #======================================================================
    # IFC Dataset Extension: 
    # This include statement must be processed last in the PCF
    # Lock is required on IFC_WORKSET variable to prevent changes at the USER level
    #====================================================================== 
      	# Enables the Dataset to be extended to include IFC2x3 property sets.
      	# IFC_WORKSET=0, dataset not extend, 
     	# IFC_WORKSET=1, dataset extended with IFC psets
     	# IFC_WORKSET=2, dataset extended with IFC psets Plus FM Handover(COBie)
    
      	IFC_WORKSET : 2
      	%lock IFC_WORKSET
        
      	%if $(IFC_WORKSET)==1 || $(IFC_WORKSET)==2
        		%if exists ($(IFCDIR)Dataset.cfg)
          			% include $(IFCDIR)Dataset.cfg
        		%endif
      	%endif
  3. 将值更改为 012,并在关闭之前保存该文件。
    注释: 要使新值生效,必须完全关闭 OpenBuildings Designer,然后重新启动应用程序。